Modbus RTU Unsolicited OPC Server

Product #
OPC-MDBUS-NA00
$795 Modbus Unsolicited OPC Server Free OPC Server Demo Email a FriendNeed more Information?

Overview

Overview

Kepware's 32 bit Modbus RTU Slave device driver works in conjunction with our OPC Server KEPServerEX, to provide data exchange between OPC Clients and a Modbus RTU network. The Modbus RTU Slave driver allows a OPC client application to appear as 1 to 247 Modbus RTU devices on the network. The slave mode allows the server to receive data by exception from a Modbus RTU master. Typical applications include connectivity with larger DCS systems that utilize Modbus RTU. As with any slave device, the Modbus RTU Slave driver will only transfer data when being read or written by a RTU master. Data integrity is ensured with our extensive error handling.

This driver is part of the Modicon Modbus Communications Suite. Purchasing either the Modbus RTU OPC Server, Modbus RTU Slave OPC Server, Modbus ASCII OPC Server, Modbus Plus SA85 OPC Server, or the Modbus Ethernet TCP OPC Server entitles you to all five drivers.

Modbus RTU Unsolicited OPC Server

Devices

Supported Devices

Device Note
Any Modbus compatible devices.  

Features

Specific Driver Features

Specific

Specific Driver Features

  • Modbus RTU Multi-drop Supported
  • Can appear as Multiple Modbus Slave devices.
  • Station numbers selectable from 1-247.
  • Full Address Range Support ( 0 - 65535 ).
  • Hex Addressing Support (0-FFFF)
  • Adjustable Address Base ( 0 or 1 )
  • Word Order Swapping on Floating Point and Long
  • Data Modbus RTU functions accepted by Slave: 01, 02, 03, 04, 05, 06, 16

General

General Driver Features

OPC/DDE

OPC/DDE Features

Learn more about OPC - Open Process Control

HMI/Client

HMI/Client Features

KEPServerEX has been enhanced to provide the widest range of connectivity of any server product available. KEPServerEX supports the following client server technologies:

To see a list of HMI's and Clients that we support go to our HMI / Client Support page.

Required

Required Software and Hardware

Supported Operating Systems
  • Windows NT
  • Windows 2000
  • Windows Server 2003
  • Windows XP

PC Hardware

Minimum
  • 400 Mhz Pentium CPU
  • 128 Megs of RAM
  • 100 Megs of Free Hard Drive Space

Recommended
  • 600 Mhz Pentium CPU
  • 512 Megs of RAM
  • 100 Megs of Free Hard Drive Space

Hardware Requirements
  • For Device and Hardware Requirements see the Devices tab.
  • Hardware Accessories

Protocol

Communication Protocol

  • Modbus RTU Protocol.