Loading...

ABB Totalflow

Licensing starts at $1272.00
Download Free Demo

Product Overview

The ABB Totalflow driver for KEPServerEX connects to ABB Totalflow devices that support the native Totalflow serial protocol. The Totalflow protocol is typically used in upstream Oil & Gas for process control and hydrocarbon measurement at the wellhead, as well as in midstream Oil & Gas facilities. Its capabilities provide data to SCADA, HMI, and measurement applications. The ABB Totalflow driver also collects historical Electronic Flow Measurement (EFM) gas and liquid data to work in conjunction with the EFM Exporter.

Resources

Performance

  • Supports communications via:
    • Ethernet Encapsulation
    • Dialup Modem
      • Automatic Dialing
      • Multiple phone numbers
  • String support
  • Supports up to 1024 communication channels
  • Supports scan mode for controlling client poll rates
  • Supports the retrieval of Trend Logs that are stored locally on the device and makes them available via CSV format
  • Supports the retrieval of gas and liquid EFM data
  • Device auto-demotion
  • Time synchronization on EFM poll, user-specified interval, or time of day
  • Media Level Redundancy
  • Supports user-defined block sizes that are configurable on-the-fly
  • Communication Serialization

Protocols

  • ABB DB1
  • ABB DB2

Supported Devices

  • ABB Totalflow 6000 series FCU
  • ABB Totalflow 6000 series microFLO
  • ABB Totalflow 6000 XSeriesG3
  • ABB Totalflow 6000 XSeriesG4

Available Languages

  • English

Application Support

  • DDE Format CF_Text and AdvancedDDE
  • NIO Interface for iFIX
  • OPC .NET Service (OPC .NET) Version 1.00
  • OPC Alarms and Events (OPC AE) Version 1.10
  • OPC Data Access (OPC DA) Versions 1.0a, 2.0, 2.05a, and 3.0
  • OPC Unified Architecture (OPC UA) Version 1.02
  • SuiteLink and FastDDE for Wonderware

Release Notes

6.4.321.0

12/13/2017

  • Increased the maximum EFM meter count to 128.
  • Fixed an issue where the _PercentValid and _PercentReturn advanced statistics tags were not displaying valid results.
  • Now correctly handles Trend File Tags where the file name contains a period/dot '.' character.

6.3.273.0

9/27/2017

  • Added additional options for time synchronization:
    • Only allow time synchronization when the difference between device and system time exceeds a certain threshold.
    • Perform a time synchronization on an EFM poll.

6.2.429.0

6/8/2017

  • Resolved an issue where device Time Sync failed if 'Idle Time Before Close' was set to 0 (in channel properties).

6.1.601.0

4/4/2017

  • Disabled time synchronization when data collection is disabled for an ABB Totalflow device.
  • Corrected an issue where all EFM records would not be retrieved when the device's internal EFM record sequence number rolled over.

6.0.2107.0

11/15/2016

  • Meters are now represented in the Project Tree View to improve visibility and editing.

5.21.114.0

3/20/2017

  • Corrected an issue where all EFM records would not be retrieved when the device's internal EFM record sequence number rolled over.

5.20.396.0

5/3/2016

  • Increased the maximum number of EFM meters allowed to 70 for Totalflow DB2 format.

5.19.467.0

10/20/2015

  • Resolved an issue where missing records on the device could prevent the Trend File upload from completing.
  • Added an error for when the protocol version is not set correctly.

5.18.662.0

6/23/2015

  • Enhanced the driver to support Trend File uploads. The new Trend File feature supports:
    • Publishing trend data to a CSV file
    • The ability to limit uploads based on time parameters
    • Optimized data uploads in limited-bandwidth scenarios (via segmented requests)
    • Scheduling uploads with the Scheduler Plug-in,
  • Enhanced the driver to support Advanced Statistics tags, including "_CommFailures" and "_ErrorResponses".
  • Enhanced the driver to support liquid EFM for model 6000 XSeriesG4
  • Support Gen4 devices for liquid using the DB2 protocol.
  • Support for hourly history, daily history, batch, liquid product, alarms, and events.
  • Support for a single Totalflow device with both liquid and gas meters.
  • No longer perform a time synchronization operation on startup when the Time Sync Method is Absolute.

5.17.495.0

2/24/2015

  • Increased the maximum channel limit from 512 to 1024.

5.15.585.0

7/22/2014

  • Fixed an issue where writes would not be processed when multiple devices on a channel were configured to use a Register Requests/Packet setting greater than 1.
  • Enhanced the driver to cache the pointer file to disk so that it will not re-poll for data already collected on server start-up.
  • Fixed an issue that would cause the driver to re-poll records starting at sequence number one in the event that the sequence number is less than the archive capacity.

5.14.491.0

2/18/2014

  • Increased the ABB Totalflow Driver's maximum channel limit from 256 to 512.

5.13.191.0

10/15/2013

  • Increased the maximum number of supported channels from 100 to 256.

5.12.140.0

6/18/2013

  • Updated the driver to convert flow times reported by Totalflow devices in integer seconds to floating-point minutes. This makes flow times exported by the EFM Exporter for Totalflow meters consistent with other meter types.

5.11.250.0

3/5/2013

  • Improved the driver's EFM data collection performance and efficiency when intermittent communication errors are seen with the connection to the EFM data source. The optimizations are handled in the driver automatically and no project configuration changes are required in the driver UI.
  • Added DB1 as a supported Protocol Version of the driver to support G1 and early G2 Totalflow FCUs. The default setting for the driver is DB2 so users must edit Totalflow Settings to select DB1 for applicable devices in the server project.
  • Fixed an issue where the Access Type for Characteristic tags was set to Read/Write when it should have been Read Only.

5.10.205

11/13/2012

Initial release of the new driver with support for real-time and EFM communications. This release provides support for connectivity to Totalflow devices using the native DB2 protocol. The driver is a serial driver but supports Ethernet Encapsulation. The driver can be selected for installation independently or as part of the Oil & Gas Suite.

Features when Part of the EFM Suite:

  • EFM Support
  • EFM Configuration and Mapping
    • History, including Gas Chromatograph data
      • Hourly
      • Daily
    • Alarms
    • Events

What Is a Driver?

KEPServerEX is more than an OPC server—it's a connectivity platform for industrial automation and IoT. Simply download KEPServerEX, and then select from Kepware's library of more than 150 device drivers, client drivers, and advanced plug-ins to fit the communication requirements unique to your industrial control system.

A driver is a software component that enables KEPServerEX to meet the connectivity requirements of a specific device, system, or other data source. The driver handles all proprietary communications to the data source for KEPServerEX; the client interfaces handle all supported OPC, proprietary, and open standards connectivity to applications that monitor or control the devices.

Drivers may be licensed individually or in suites. Additional drivers can be licensed on demand as connectivity needs evolve.

Purchasing Information

ABB Totalflow

Subscription

Pay an annual fee to use the software. Support & Maintenance is included.

$1272.00/yr.