产品概览
适用于 KEPServerEX 的 Allen-Bradley ControlLogix Unsolicited 驱动用作仿真 Allen-Bradley ControlLogix PLC,允许在 KEPServerEX 和 Allen-Bradley Logix 设备之间进行主动通信,可消除不必要的 PLC“读取”通信。此驱动支持 Logix 系列控制器的“CIP 数据表读取和写入消息”功能。通过 Logix 主站读取或写入时,ControlLogix Unsolicited 驱动将仅传输数据。数据获取将通过 KEPServerEX 基于主需求自动优化。
资源
性能
- 自动生成标签数据库
- 符号读取/写入支持
- 分散和完整的读取/写入支持
- 未连接的消息支持
- 高级符号标签寻址支持
- 高级错误处理
- 符合 ODVA
- 连接的消息支持
- 通过 TCP 和 UDP 提供身份请求支持
应用程序支持
- DDE Format CF_Text and AdvancedDDE
- NIO Interface for iFIX
- OPC .NET Service (OPC .NET) Version 1.00
- OPC Alarms and Events (OPC AE) Version 1.10
- OPC Data Access (OPC DA) Versions 1.0a, 2.0, 2.05a, and 3.0
- OPC Unified Architecture (OPC UA) Clients
- SuiteLink and FastDDE for Wonderware
发行说明
6.13.250
2023/1/26
- Fixed an issue adding and editing tags in a valid collection of Logix Tags.
6.11.718.0
2021/12/21
- Removed non-inclusive terms out of respect for users of our software.
- Renamed this driver (from Allen-Bradley ControlLogix Slave Ethernet / Allen-Bradley ControlLogix Unsolicited) in compliance with updated terminology.
6.9.636.0
2021/8/10
- Fixed an issue where re-importing the .csv file could cause tag generation to fail or be incomplete.
6.6.348.0
2018/11/14
- 更新了 Native 标记数据库,使之可以在“配置 GUI”(Configuration GUI) 中操作或通过“配置 API”(Configuration API) 操作。
5.13.191.0
2013/10/15
- Enhanced the driver to support ODVA Conformance. New features include Connected Messaging, ODVA Member ID, and EDS file.
- Improved error handling so that unsupported data types (such as BCD and LBCD) will result in an "Invalid data type" error message instead of an "Out-of-range" error message.
- Corrected a problem in dimension detection for tag paths that contain 16 bit element offsets.
- Corrected a defect in element count calculation that was exposed by the Allen-Bradley Micro800 Ethernet Driver. The element count is now correct if the element offsets indicate that less than the specified element count need to be returned.
- Runtime tag values are no longer reset when a device's slot configuration is changed.
- Removed support that allowed users to specify Port 0 (system determined) for the EIP server binding. Because the driver binds a listen socket to both UDP and TCP for conformance, these ports must be the same.
- Removed the potential server hang that could occur if EIP messages were being processed while a channel's Network Interface or Port was changed.
- Corrected int64<->Double conversion to match behavior in ControlLogix Ethernet Master Driver.
- Removed support for the Media-Level Redundancy Plug-In because it was never intended.
5.11.250.0
2013/3/5
Added support for strings of INT and DINT arrays.
5.8.109.0
2012/2/21
Initial release of the new driver. It is licensed with either the Allen-Bradley Driver Suite or the Manufacturing Suite, and requires that new licenses be purchased for access. This driver is intended for customers that require the use of CIP Data Table Read and Write Messages from the Logix family of controllers and need to communicate with a driver in an OPC server.