正在加载……

Fisher ROC Plus Ethernet

参见购买信息了解更多详情
Download Free Demo

产品概览

Fisher ROC Plus Ethernet 驱动与 KEPServerEX 结合使用,以便在 OPC/DDE 客户端与 ROC Plus 协议设备之间交换数据。此驱动旨在配合以下 ROC Plus 协议设备使用:ROC809、ROC809L、ROC827 和 ROC827L。

资源

性能

  • 支持直接从 RTU 或配置文件自动生成标签,以快速部署通信
  • 通信规范
  • 运算符识别
  • 针对 EFM 轮询、用户指定的间隔或时间的时间同步
  • 用户程序数据(用户定义的点)的读写和自动标签生成
  • 支持 OpCode 10 和 11 以读写用户表
  • 支持 OpCode 167 以进行单点读取
  • 支持 OpCode 180 以便在单一请求中进行多点读取
  • 支持高级统计数据标签,包括 _CommFailures、_ErrorResponses 等
  • 针对极端条件(嘈杂的通信通道和低带宽)优化

协议

  • ROC Plus

支持的设备

  • ROC809
  • ROC827

可用语言

  • 英语

应用程序支持

  • DDE Format CF_Text and AdvancedDDE
  • NIO Interface for iFIX
  • OPC .NET Service (OPC .NET) Version 1.00
  • OPC Alarms and Events (OPC AE) Version 1.10
  • OPC Data Access (OPC DA) Versions 1.0a, 2.0, 2.05a, and 3.0
  • OPC Unified Architecture (OPC UA) Clients
  • SuiteLink and FastDDE for Wonderware

发行说明

6.10.623.0

2021/2/23

  • Removed non-inclusive terms out of respect for users of our software.

6.9.572.0

2020/6/2

  • Fixed an issue where FisherROC Ethernet devices in a virtual network using the Scheduler would cause high CPU utilization.
  • Fixed an issue where a late-arriving Opcode 135 response would get applied to the wrong point.
  • Fixed an issue where the driver did not release the communication port when releasing communication control in a virtual network.

6.7.1046.0

2019/6/18

  • Corrected EFM exporter output for Meter Type and Calculation Method using polled device settings. 
  • Added _System tags for _DeviceAddress and _DevicePort. 

6.4.321.0

2017/12/13

  • 将点类型 177 的地址表中的参数 #0(设备标签)的参数大小从 10 字节更新为 40 字节。

6.3.273.0

2017/9/27

  • 增加了更多有关时间同步的选项:
    • 仅在设备时间与系统时间之差超过某个阈值时才允许时间同步。
    • 对 EFM 轮询执行时间同步。

6.1.601.0

2017/4/4

  • 当禁用数据收集时,禁止时间同步。
  • 为 H2、HE、CO 和 AR 添加了缺失的气体属性映射。
  • 为气体模型启用了点类型 93、94。

6.0.2107.0

2016/11/15

  • 现在,仪表呈现在项目树状视图中,以改进可见性和编辑能力。
  • 解决了以下问题:avg_c8、avg_c9 和 avg_c10 的 EFM 数据无法导出到 CSV。
  • 纠正了 n-Pentane 和 neo-Pentane 的 EFM 数据的列映射。

5.20.396.0

2016/5/3

  • Resolved a Time Sync issue where, if no reads are active; only the first four (4) devices successfully synchronize.
  • Enhanced the driver to allow UDP tags to use the correct data type set (not default). This allows the data type of these tags to be manually modified.
  • Enhanced the driver to support parameters 56 through 112 to Point Type 141.

5.19.467.0

2015/10/20

  • Added support for Advanced Statistics Tags, including _CommFailures, _ErrorResponses, and more.
  • The driver now includes the #n syntax when auto-generating tags for similarly named point types in point type tables to avoid duplicate tag names. This may change the default name for some auto-generated tags from previous versions.
  • Changed the alarm state from OFF to On for string events.
  • Resolved an issue where attempting to read a tag from a non-responsive device could falsely cause a timeout when reading the next tag on a different device.
  • Resolved an issue where reading multiple tags in the same point type logical could result in two separate read requests rather than one.
  • Corrected mappings for liquid temperature high and low limits to EFM exports.

5.18.662.0

2015/6/23

  • New Ethernet driver. Supports multiple ROC Plus devices per channel, with each device having its own IP address.
  • Added support for reading and writing to user tables using Opcodes 10 and 11.
  • Added the ability to ignore extra bytes received on the wire that are not part of the ROC communications. These bytes are sometimes added by radio modems and other networked equipment.
  • Enhanced the drivers to support Opcode 180. Enabled per device, this allows the driver to read multiple TLP and UDPs per read request.

功能(包含在 EFM Suite 中时)

  • 支持气体和液体电子式流量测量 (EFM)
  • EFM 配置和映射
    • 历史记录,包括每小时和每天的气相色谱仪数据
    • 成批
    • 液体产品
    • 警报
    • 事件

要求

  • ROC800L (W68258) 固件版本 1.30 或更高版本
  • Liquid Calcs 版本 1.03.00 (W68259) 或更高版本
  • Batching 版本 1.03.00 (W68260) 或更高版本