正在加载……

Omron FINS Ethernet

参见购买信息了解更多详情
Download Free Demo

产品概览

Omron FINS Ethernet 驱动与 KEPServerEX 协同工作,通过 UDP/IP 在 OPC 客户端和使用 Omron FINS 协议的 PLC 之间交换数据。它还支持 Sysmac Link 操作,以通过 Sysmac Net 访问其他 PLC。KEPServerEX 可根据客户端的需求自动优化数据采集,并通过强大的错误处理能力确保数据完整性。

资源

性能

  • 支持 UDP/IP 通信
  • 支持 FINS 网关以允许 Sysmac Link 和 Sysmac Net 访问
  • 支持辅助继电器

协议

  • Omron FINS over Ethernet

支持的设备

  • Devices Supporting FINS protocol via Sysmac Way: Host Link Interface

可用语言

  • Simplified Chinese
  • 日语
  • 英语

应用程序支持

  • DDE Format CF_Text and AdvancedDDE
  • NIO Interface for iFIX
  • OPC .NET Service (OPC .NET) Version 1.00
  • OPC Alarms and Events (OPC AE) Version 1.10
  • OPC Data Access (OPC DA) Versions 1.0a, 2.0, 2.05a, and 3.0
  • OPC Unified Architecture (OPC UA) Clients
  • SuiteLink and FastDDE for Wonderware

发行说明

6.2.460.0

2017/7/6

  • 增加了中文支持。

6.0.2107.0

2016/11/15

  • 添加了对中文、日语和韩语 (CJK) 字符的支持。
  • 增加了日语支持。

5.18.662.0

2015/6/23

  • Enhanced error detection to support remote network errors to place the device in error state. This more accurate reporting supports redundancy failover.

5.17.495.0

2015/2/24

  • Corrected an issue where the driver would produce a syntax error during tag validation if the data type was not supported. Some clients add items with a set data type regardless of the address. The driver now responds with bad type, allowing the driver library to validate again with the default type.

5.15.585.0

2014/7/22

  • Increased the maximum channel limit to 512.

5.6.122.0

2011/7/25

  • Added the ability to select the behavior when writes are issued to TS and CS addresses (when the PLC is in Run Mode). Before, these writes would fail and an error would be logged. Options also exist to set the PLC to Monitor Mode and to perform the write, or to set the PLC to Monitor Mode, perform the write, and then reset the PLC to Run Mode.

5.4.131.0

2010/10/28

  • Added support for the CJ2 Model.
  • Added the reporting of device-level error conditions and detection of network relay error frames. We now output the following error messages instead of posting "Device not responding" messages:
  • Modified the driver to handle the relay error frame when a fatal CPU error is present. The error messages were also updated to include "Main, Sub:" and "Net Addr, Node Addr:" in decimal notation: this should make it easier for users to compare to Device Property settings in the server project.

     • Network relay error.[Net Addr, Node Addr: '0x00, 0x3A'], [End Code: '0x8302']

     • Fatal CPU Unit error.[End Code: '0x0080']

     • Non-fatal CPU Unit error.[End Code: '0x83C2']

5.3.118.0

2010/6/9

  • Fixed Address Hints for the C500 IR register.
  • Added 2 new string types:

    • XXX as string with Only the Low Order byte (LSB - least significant 8-bits) of each word is used for

      read/write. , Syntax: XXXaddr.lenE

    • XXX as string with Only the High Order byte(MSB - most significant 8-bits) of each word is used for

      read/write. , Syntax: XXXaddr.lenD

5.2.133.0

2010/2/18

  • Fixed thread synchronization issue which could result in intermittent stale communications for certain channels in multi-channel projects

5.1.71.0

2009/10/21

  • Fixed thread synchronization issue which could result in intermittent stale communications for certain channels in multi-channel projects
  • 有关支持 Sysmac Way(Host Link 接口)的当前模型列表,请访问制造商网站。