Kepware Knowledge Base: Solution


Connecting to MicroLogix 1110's Built-In Ethernet Port


Last Update: 2018/11/7

In KEPServerEX version 4.190.341 and later, Kepware's Allen-Bradley ControlLogix Ethernet Driver supports connecting to MicroLogix 1110's built-in Ethernet port. For more information, refer to the instructions below.

  1. To start, open KEPServerEX and create a new channel. In Device Driver, select Allen-Bradley ControlLogix Ethernet.
  2. Continue through the Channel Wizard, specifying the channel settings as desired. Once complete, click Finish.
  3. Next, add a device to that channel. In Device Model, select MicroLogix 1100.
  4. In Device ID, enter the IP Address of the PLC.
  5. Continue through the Device Wizard, specifying the device settings as desired. Once complete, click Finish.